Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.421 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.453 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AMPS | CURRENT RATING IN AMPS | 10.0 |
ABGN | BOARD OVERALL LENGTH | 7.781 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-N-290,CLASS 1,TYPE 8 FED SPEC 1ST TREATMENT RESPONSE TERMINALS |
ABGQ | BOARD OVERALL HEIGHT | 1.203 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CQCW | FEEDTHRU CONNECTION END TYPE | F4 15TH MATERIAL RESPONSE BOTH ENDS |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 FOURTH COMBINATION BOTH ENDS |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.421 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.578 INCHES |
CRZR | FEEDTHRU TERMINAL QUANTITY | 16 SINGLE COMBINATION |
CWLN | TERMINAL DESIGN | LINKED VERTICAL FEEDTHRU |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 16 SINGLE |
ABGS | BASE THICKNESS | 0.391 INCHES |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
ABGP | BOARD OVERALL WIDTH | 1.125 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.352 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAMA | MOUNTING HOLE DIAMETER | 0.203 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3400.0 |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS AND TIN TERMINALS |
AAQL | BODY STYLE | BARRIER TYPE |